  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
8
G
Terminal Block
Conduit panel
Conduit
Outdoor unit
Covered conduit connection for size 18k only
L1 L2 GND L1 L2 S L1 L2 GND S
Ground Control Ground Control
E
Unit "A"
Power and Control Signal to
Two or Four Terminal Blocks
One Terminal Block
38GXM-40GXM018, 024 & 030 Connection Diagram
This Series of Connections Will be Repeated for Each Indoor Unit (A to A - B to B etc.)
Indoor Unit Power and Control Signal
One Terminal Block
208/230-1-60
CONNECTING CABLE
OUTDOOR TO INDOOR
Supply
Indoor Unit
Pow e r
Supply
208/230-1-60
Main
Pow e r
208/230-1-60
Pow e r to
Indoor
Unit
A09656a
Fig. 11 --- Field Wiring
INSTALL ALL POWER, INTERCONNECTING
WIRING, AND PIPING TO INDOOR UNIT.
1. Run interconnecting piping and wiring from outdoor unit to
each indoor unit (in matched pairs).
2. Pass interconnecting cable through hole in wall (outside to
inside).
3. Lift indoor unit into position and route piping and drain
through hole in wall (inside to outside). Fit interconnecting
wiring into back side of indoor unit.
4. Hang indoor unit on upper hooks of wall mounting plate (as
shown in Fig. 12)
A08283
Fig. 12 --- Hanging Indoor Unit
5. Open front cover of indoor unit and remove field wiring ter-
minal block cover (see Fig. 13)
Field Wiring
Cover
Interconnecting
Cable
A08279
Fig. 13 --- Field Wiring Cover
6. Pull interconnecting wire up from back of indoor unit and
position in close to the terminal block on indoor unit.
7. Push bottom of indoor unit onto mounting plate to com-
plete wall mount.
8. Connect wiring from outdoor unit per connection diagram
(see Fig. 11).
NOTE: Polarity of power wires must match original
connection on outdoor unit.
9. Replace field wiring cover and close front cover of indoor
unit.
10. Connect refrigerant piping and drain line outside of indoor
unit. Refer to Fig. 8 for proper installation of flare connec-
tions. Complete pipe insulation at flare connection then
fasten piping and wiring to the wall as required. Com-
pletely seal the hole in the wall.
11. Repeat steps 1 through 10 for each indoor unit.