Installation Instructions
38GVM / 40GVM
Multi---Split High---Wall Ductless Split System
38GVM --- Size 18k, 24k, 30k, 36k and 42k
40GVM --- Size 9k, 12k, and 18k
NOTE: Read the entire instruction manual before starting the installation.
A12567
38GVM
40GVM
TABLE OF CONTENTS
PAGE
PARTS LIST 2.......................................
SAFETY CONSIDERATIONS 3.........................
SYSTEM REQUIREMENTS 3--4........................
DIMENSIONS 5--7....................................
CLEARANCES 7--8...................................
INSTALLATION GUIDE 9.............................
INDOOR UNIT INSTALLATION 9.......................
OUTDOOR UNIT INSTALLATION 10--11.................
SYSTEM VACUUM AND CHARGE 12...................
START--UP 13........................................
TROUBLESHOOTING 14--15...........................
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1 - Installation Instructions

Installation Instructions38GVM / 40GVMMulti---Split High---Wall Ductless Split System38GVM --- Size 18k, 24k, 30k, 36k and 42k40GVM --- Size 9k, 12k,

Pagina 2 - PARTS LIST

10OUTDOOR UNIT INSTALLATION1. Use a rigid base to support unit in a level position.2. Locate outdoor unit and connect piping and wiring.CAUTION!EQUIPM

Pagina 3 - SYSTEM REQUIREMENTS

11GGTerminal BlockConduit panelConduitOutdoor unitCovered conduit connection for size 18k onlyL1 L2 GND L2 S L1 L2 S L1 GNDGround Ground208/230 Low V

Pagina 4

12SYSTEM VACUUM AND CHARGEUNIT DAMAGE HAZARDFailure to follow this caution may result in equipmentdamage or improper operation.Never use the system co

Pagina 5 - DIMENSIONS -- OUTDOOR

13START--UPTest OperationPerform test operation after completing gas leak and electricalsafety check.1. Push the “ON/OFF” button on Remote Control to

Pagina 6

14TROUBLESHOOTING38GVM Diagnostic Codes18, 24, and 30K36 and 42KIndoor UnitDisplayWiredControlIndoor and/orOutdoor UnitErrorNA Defrost Mode 1 08 NA Ou

Pagina 7 - CLEARANCES -- INDOOR

15TROUBLESHOOTING (CONTINUED)ErrorCodeTableErrorCodeError DescriptionErrorCodeError DescriptionErrorCodeError Description13Unit A indoor pipe outlet t

Pagina 8 - CLEARANCES -- OUTDOOR

16Copyright 2012 CAC / BDP S 7310 W. Morris St. S Indianapolis, IN 46231Manufacturer reserves the right to change, at any time, specifications and des

Pagina 9 - INDOOR UNIT INSTALLATION

2PARTS LISTPart No. Part Name Qty1 Mounting Plate 12 Mounting Screws 53 Remote Control 14 Remote Control Holder 15 Conversion Joint Varies. See CJ Tab

Pagina 10 - 38/40GVM

3SAFETY CONSIDERATIONSInstalling, starting up, and servicing air--conditioning equipmentcan be hazardous due to system pressures, electrical component

Pagina 11

4Refrigerant ChargeUnit SizeChargeoz. (kg.)Additional ChargeRequired After ft. (m)Additional Chargeoz./ft. (g/m)Metering Device18 K 47.6 (1.35) 20 (6.

Pagina 12 - SYSTEM VACUUM AND CHARGE

5DIMENSIONS -- INDOORHDWA08289Unit SizeWIn. (mm)HIn. (mm)DIn. (mm)Net Operating WeightLbs. (Kg)9k 33.3 (846) 10.7 (272) 7.1 (180) 22.0 (10)12k 33.3 (8

Pagina 13 - START--UP

6DIMENSIONS -- OUTDOOR (CONTINUED)35.1 (892)37.2 (946)27.6 (700)15.6 (396)13.4 (341)22.0 (560)14.5 (368)Unit: in. (mm)A12553Fig. 4 --- 38GVM024/030024

Pagina 14 - TROUBLESHOOTING

7DIMENSIONS -- OUTDOOR (CONTINUED)3.0(76)17.7 (450)3.9(99)40.0 (1015)43.4 (1103)42.8 (1087)7.5(191)24.8 (631)17.3 (440)15.8 (401)14.3 (362)4.8(121)Uni

Pagina 15 - TROUBLESHOOTING (CONTINUED)

8CLEARANCES -- OUTDOOR11.8 (300)minimumdistance fromwall11.8 (300)minimum spaceon air inlet side24.0 (610)minimum spaceon service valve side78 (2000)m

Pagina 16

9INSTALLATION GUIDEUp to four fan coil units can be connected to one outdoor unit.Refer to the Product Data for approved combinations.Ideal installati